Duo System

Precise marking of breast lesions

Anchoring

Secure anchoring in tissue through the double hook with sharp tips

Brusttumor Lokalisation, Clipmarkierung, biopsy site marker

Repositioning

Wire can be pulled back into the cannula and released again

Single-handed operation

Duo System Premium for ultrasound-guided operation using one hand

Duo System

Twisted localization wire

Duo System is used for marking non-palpable, suspicious breast lesions prior to surgery. The flexible marking wire facilitates the intraoperative localization of findings for surgeons. 20-gauge thin, sharp puncture cannulas ensure minimally invasive treatment.

  • Flexible marking wire made from Nitinol for intraoperative localization of findings
  • Distal double hook expands upon deployment and anchors firmly in the tissue
  • Sharp tips of the hooks assist penetration of tumor tissue
  • Position can be corrected by pulling wire back into cannula
  • Varying twisting for intraoperative depth orientation
  • Duo System deployment systems are designed for a range of applications

The localization wire is pushed out of the cannula. The double hook expands upon deployment and anchors firmly in the tissue.

Duo System localization kits

The choice is yours

Wire localization

Duo System

  • With 20-Gauge puncture cannula
  • Puncture cannula suitable for stereotactic surgery
  • Position can be corrected by pulling wire back into cannula
  • Cannula with depth markings
  • Sharp and echogenic cannula tip
Wire localization

Duo System Premium

  • With 20-Gauge puncture cannula and ergonomic handle
  • Handle for ultrasound-guided operation using one hand
  • Position can be corrected by pulling wire back into cannula
  • Cannula with depth markings
  • Sharp and echogenic cannula tip with ultrasonically visible marking
Wire localization MRI

MRI Duo System

  • With MRI compatible 20-Gauge puncture cannula for MRI-guided wire localization made from nickel-cobalt
  • Suitable for MRI procedures up to three Tesla
  • Position can be corrected by pulling wire back into cannula
  • Cannula with depth markings

Duo System in mammography

Duo System image gallery

Order information

Wire localization
Product code Gauge Ø Cannula length
Duo System 271440 20 0,95 mm 50 mm
271441 20 0,95 mm 90 mm
271443 20 0,95 mm 120 mm
Duo System Premium 271770 20 0,95 mm 50 mm
271771 20 0,95 mm 90 mm
271773 20 0,95 mm 120 mm
MR Duo System 601609 20 0,95 mm 90 mm
601611 20 0,95 mm 120 mm

Packaging unit: 10 items, shelf life from production date: 5 years

Order information

Drahtmarkierung

Product code Duo System
271440 / 20 G / 50 mm
271441 / 20 G / 90 mm
271443 / 20 G / 120 mm

Product code Duo System Premium
271770 / 20 G / 50 mm
271771 / 20 G / 90 mm
271773 / 20 G / 120 mm

Product code MR Duo System
601609 / 20 G / 90 mm
601611 / 20 G / 120 mm

Packaging unit: 10 items, shelf life from production date: 5 years

Leave a message.

2 + 14 =

Information on data processing can be found in our privacy policy.