    Product information

    Product details at a glance:

    Puncture system with Lock-Wire technology for the retrieval of bone marrow samples for histological evaluation

    Guaranteed securing of the biopsy specimen in adequate quantity and quality that meets the requirements

    Uncomplicated use for significantly reduced patient trauma

    Significant reduction of the pressure applied by the operating physician

    Puncture cannula:

    Made of stainless steel

    Offers great stability

    • Tapered tip
    • Internal trocar with sharp-ground diamond point enables easy penetration of the cortex
    • Biopsy slide with measurement function and application support included in the material supplied

    Lock-Wire technology:

    • Lock Wire made of nitinol
    • Special construction of the Lock-Wire ensures perfect securing of the bone marrow specimen in the cannula
    • Quantity and quality of the biopsy specimen meet the requirements of pathological analyzability
    • No squeeze artefacts or other impairments to the sample
    • Significantly reduced patient trauma and simultaneously reducing the pressure applied by the physician performing the puncture

    Handle:

    • Ergonomic handle permits optimum control of the pressure application
    • Additional closure cap reduces the leakage of blood at the proximal end of the puncture cannula
    • Luer-Lock connector to attach syringes for vacuum-supported biopsy retrieval

    • Packaging Unit: 10 piece

    The SOMATEX® Safe Cut Bone Marrow Puncture System for collecting histological tissue from the iliac crest is equipped with the specially developed Lock-Wire technology that guarantees sufficient quantity and optimum securing of the biopsy material in the puncture cannula.

    Puncture cannula:
    The puncture cannula of the Safe Cut Puncture System is made of stainless steel, offers maximum stability and has a tapered tip. The trocar positioned in the puncture cannula is equipped with an extremely sharp diamond-ground point that allows easy penetration of the cortex.

    Lock-Wire technology:
    Following the puncture, after the biopsy specimen has been cut and adequately checked for length with the aid of the biopsy slide, the Lock-Wire supplied with Safe Cut is inserted into the opening of the grip of the puncture cannula. In the process the sample is separated from the medullary cavity and the puncture cannula can be removed from the iliac crest. The special design of the Lock-Wire thereby ensures perfect securing of the biopsy specimen in the cannula.* In addition, the result complies with the requirements needed for the pathological evaluation in terms of sufficient quantity and with regard to the quality of the sample. The bone marrow sample is guaranteed to be free from squeeze artefacts and other sample impairments. The Lock Wire is made of nitinol.

    The simplified handling compared with conventional puncture systems also leads to significantly reduced patient trauma together with the simultaneous reduction in the pressure applied by the operating physician.

    Handle:
    The ergonomic handle of the Safe Cut Biopsy System allows for optimum pressure application during use. A closure cap additionally supplied with the needle grip helps to prevent blood from leaking from the proximal end of the cannula. Vacuum-supported biopsy collections are supported by a Luer-Lock connector to attach syringes.

    *Study by ArtiMed Medical Consulting, performed at the Homburg/Saar Hospital and elsewhere in routine practice.

    Uhl, M., Theves, C., Geiger, J., Kersten, A., & Strohm, P. C. (n.d.). [The percutaneous bone biopsy: in vitro study for comparison of bone biopsy needles]. Zeitschrift Für Orthopädie Und Unfallchirurgie, 147(3), 327–33. doi:10.1055/s-2008-1039140

    Downloadable materials

    Video

    Abstracts

    * Studie der ArtiMed Medical Consulting, die im Rahmen der klinischen Routine u. a. an der Uniklinik Homburg/Saar durchgeführt wurde.


    Uhl, M., Theves, C., Geiger, J., Kersten, A., & Strohm, P. C. (n.d.). [The percutaneous bone biopsy: in vitro study for comparison of bone biopsy needles]. Zeitschrift Für Orthopädie Und Unfallchirurgie, 147(3), 327–33. doi:10.1055/s-2008-1039140

    Request for quotation

  • Reload captcha
  • * required information