Breast tumor localization

Advanced solutions for biopsy site marking and wire localization

Our tissue markers and localization wires enable precise and patient-friendly marking of breast lesions in the tissue. This is ensured by sharp puncture cannulas and ergonomic handle design. All markers and wires are made from the biocompatible implant material Nitinol.

Biopsy tissue markers from the Tumark family enable precise and patient-friendly marking of biopsy sites and suspicious lesions in the tissue. This is ensured by 18 gauge thin, sharp puncture cannulas and the ergonomic handle design for single-handed operation.

Due to their geometry, the biopsy site markers become firmly anchored in the tissue and are visible under ultrasound, X-ray and MRI. All markers are made from the bio-compatible implant material Nitinol and remain visible in the tissue.

Tumark® family

Order information [Download]

Brusttumor Lokalisation, Clipmarkierung, biopsy site marker
Tumark® Vision

  • Spherical premium marker
  • Unique 3D design
  • Mesh structure made of 48 individual wires

Brusttumor Lokalisation, Clipmarkierung, biopsy site marker
Tumark® Professional

  • U-shaped marker
  • Lateral anchor feet provide secure anchoring in the tissue
  • Marker material is sandblasted and twisted

Brusttumor Lokalisation, Clipmarkierung, biopsy site marker
Tumark® Professional Q

  • Q-shaped marker
  • Q-shape becomes firmly anchored in the tissue
  • Marker material is sandblasted and twisted

Brusttumor Lokalisation, Clipmarkierung, biopsy site marker
Tumark® Q

  • Q-shaped marker with compact application system
  • Q-shape becomes firmly anchored in the tissue
  • Marker material is sandblasted and twisted

Brusttumor Lokalisation, Clipmarkierung, biopsy site marker
Tumark® Eye

  • Eye-shaped marker
  • Angled ends for better anchorage in the tissue
  • Bent shape and opening enable 360° ultrasound visibility

Brusttumor Lokalisation, Clipmarkierung, biopsy site marker
Tumark® Professional X

  • X-shaped marker
  • Lateral anchor feet provide secure anchoring in the tissue
  • Twisted marker with angled ends

Brusttumor Lokalisation, Clipmarkierung, biopsy site marker
Tumark® Vision MRI

  • MRI biopsy site marking
  • Spherical marker with cannula for MRI controlled biopsy site marking up to 3 Tesla
  • Compact construction of application system for use in the MRI gantry area

Brusttumor Lokalisation, Clipmarkierung, biopsy site marker
Tumark® MRI

  • MRI biopsy site marking
  • U-shaped marker with cannula for MRI controlled biopsy site marking up to 3 Tesla
  • Compact construction of application system for use in the MRI gantry area
Brusttumor Lokalisation, Clipmarkierung, biopsy site marker    Stability
Markers expand into shapes upon deployment and anchor firmly in the tissue
Brusttumor Lokalisation, Clipmarkierung, biopsy site marker    Single-handed operation
Ergonomic handles allow for single-handed use
Brusttumor Lokalisation, Clipmarkierung, biopsy site marker    Visibility
Intelligent marker design and material provide visibility under ultrasound, X-ray and MRI

Tumark® Vision

Spherical premium marker

With the Tumark Vision marker we have set new standards for the visibility of biopsy site markings in ultrasound.

SOMATEX localization wires allow intraoperative tumor localization for the surgeon by marking breast lesions. If it is necessary to correct the position when marking, the localization wires can easily be pulled back into the cannula and released again.

Sharp puncture cannulas ensure patient-friendly treatment. All tumor localization wires are made of the biocompatible implant material Nitinol and are available with different cannula lengths.

Order information [Download]

Brusttumor Lokalisation, Drahtmarkierung, Markerierungsdrähte
Duo System

  • Twisted localization wire
  • Secure anchoring in the tissue using a double arches design with sharp tips
  • Flexible wire with varying twisting for intraoperative orientation

Brusttumor Lokalisation, Drahtmarkierung, Markerierungsdrähte
Duo System Premium

  • Twisted localization wire with application system for single-handed operation
  • Secure anchoring in the tissue using a double arches design with sharp tips
  • Flexible wire with varying twisting for intraoperative orientation

Brusttumor Lokalisation, Drahtmarkierung, Markerierungsdrähte
Tuloc

  • Monofilament localization wire
  • Secure anchoring in the tissue using a double arches design with sharp tips
  • Monofilament rigid wire with 2 cm long distal palpable marking tube for intraoperative orientation

Brusttumor Lokalisation, Drahtmarkierung, Markerierungsdrähte
Tuloc Premium

  • Monofilament localization wire with application system for single-handed operation
  • Secure anchoring in the tissue using a double arches design with sharp tips
  • Monofilament rigid wire with 2 cm long distal palpable marking tube for intraoperative orientation

Brusttumor Lokalisation, Drahtmarkierung, Markerierungsdrähte
Q-Wire System

  • Q-shaped localization wire
  • Q-shaped wire tip provides secure anchorage
  • Flexible wire with 2 cm long distal palpable marking tube for intraoperative orientation

Brusttumor Lokalisation, Drahtmarkierung, Markerierungsdrähte
Duo System Stereo

  • Duo System localization wire with compact application system
  • Application system with rigid 18 gauge cannula providing extra stability for puncture of dense tissue
  • Compact design for constricted interventional situations such as while using 2D biopsy compression plates

Brusttumor Lokalisation, Drahtmarkierung, Markerierungsdrähte
MRI Duo System

  • MRI wire localization
  • Duo System localization wire with MRI application system for MRI controlled operations up to 3 Tesla

Brusttumor Lokalisation, Drahtmarkierung, Markerierungsdrähte
MRI Tuloc

  • MRI wire localization
  • Tuloc localization wire with MRI application system for MRI controlled operations up to 3 Tesla
Brusttumor Lokalisation, Drahtmarkierung, Markierungsdrähte, wire    Stability
Localization wires expand into shapes upon deployment and anchor firmly in the tissue
Brusttumor Lokalisation, Drahtmarkierung, Markierungsdrähte, wire    Repositioning
Localization wires can be pulled back and released again
Brusttumor Lokalisation, Drahtmarkierung, Markierungsdrähte, wire    Single-handed operation
Premium systems with ergonomic handles allow for ultrasound-guided operation